Acrel BD-AI Single Phase Current Transducer

Acrel BD series power transducer is a device that converts electrical parameters such as current, voltage, frequency, power, power factor, etc. in the power grid into linear DC analog signals or digital signals through isolation. Products comply with GB/T13850-1998, IEC-688 standards.

BD-AI Single Phase Current Transducer measures single-phase AC 0-5A current, isolated transmission output analog 4-20mA or 0-5V DC signal, and can use true RMS measurement circuit to correctly measure various sine or non-sine waves, suitable for frequency conversion Environment.

  • Input:AC 0-1A,0-5A

  • Output:DC 0-20mA/4-20mA/0-5V/0-10V

  • Power supply:DC 24V/48V AC85~265V

  • Optional function:RS485,Ture RMS

Parameters of BD-AI Single Phase Current Transducer


Type

BD-Al,BD-AV

Accuracy

Class 0.5

Input

Signal

AC0~1A,0~5A,AC 0~120V,0~300V,0-~500V

Overload

Current:continuous 1.2 times, instant current 10   times per second
  Voltage:continuous 1.2 times, instant Voltage 10 times per second

Frequency

45Hz~65Hz

Output

Signal

DC 4~20mA,0~20mA,0~5V,0~10V

Load

Current output<600Ω,Voltage output1000Ω

Optional function

RS485

Power Supply

AC 85~265V,DC 100~350V,DC 24V/48V

Temperature drift coefficient

0.2class≤100ppm℃,0.5class≤200ppm℃

Response time

<400ms

Insulation resistance

≥100MΩ

Power frequency    withstand voltage

Auxiliary power supply/Input / Output 2kV/1min,50Hz

Environment

Temperature

Work;-10℃~55℃ Store:-25℃~70℃

Humidity

≤93%RH,places without condensation and corrosive   gas

Altitude

≤2500m

Installation mode

TS35mm din rail or screw fixing



Video of BD-AI Single Phase Current Transducer

Wiring of BD-AI Single Phase Current Transducer


BD-AI Single Phase Current Transducer interface 1/2 is power supply L/N(AC 85~265V,DC 100~350V,DC 24V/48V),interface 3/4 is the current input AC 1A/5A,interface 5/6 is the first channel analog output DC 4~20mA,0~20mA,0~5V,0~10V.


Wiring of BD-AI Single Phase Current Transducer

Application of BD-AI Single Phase Current Transducer


  • Industrial automation field

  • Photovoltaic and wind power industry

  • Metallurgy, Electric Power, Oil Field

  • Railway locomotives, Shipping Industry


Package of BD-AI Single Phase Current Transducer


MINIMUM PACKAGEBd AiZmct103c ModulePackage of BD-AI Single Phase Current TransducerPackage of BD-AI Single Phase Current Transducer
MINIMUM PACKAGEPackage dimensions(1 PC)
17*15.5*12.5cm
Package Weight(1 PC)
0.25Kg
WHOLE BOX PACKAGEPackage dimensions(10 PCS)
45.5*26*19.5
Package Weight(36 PCS)
3.5kG
PRODUCT HS CODE9030339000


Looking Forward To Our Cooperation?

Any IoT energy management system problem pls contact us, our experts will reply you within 24 hours.

Send Inquiry Now
  • Tel:

    +86-18761599716

  • Address:

    No.5 Dongmeng Road, Nanzha Street, Jiangyin City, Jiangsu Province, China.