Jiangsu Acrel Electrical Manufacturing Co., LTD.
Jiangsu Acrel Electrical Manufacturing Co., LTD.
  • dc ct sensor
  • wiring of bd di single phase dc current transducer 1
  • wiring of bd di single phase dc current transducer 2
  • wiring of bd di single phase dc current transducer 3
  • wiring of bd di single phase dc current transducer 4
  • dc ct sensor
  • wiring of bd di single phase dc current transducer 1
  • wiring of bd di single phase dc current transducer 2
  • wiring of bd di single phase dc current transducer 3
  • wiring of bd di single phase dc current transducer 4

Acrel BD-DI Single Phase DC Current Transducer

Acrel BD series power transducer is a kind of device which can isolate and transmit electric parameters such as current, voltage frequency, power, power factor or temperature, resistance and so on non-electrical parameters, into linear DC analog signal or digital signal. They can directly connect with the pointer table, digital meters, also can connected with automatic control devices (eg PLC), a variety of A / D converter, and the computer system.

BD-DI Single Phase DC Current Transducer is widely used in PLC and other automation devices by measuring DC current signals, isolating and transferring analog signals to output 4-20mA/0-20mA/0-5V/0-10V. BD-DV single phase dc voltage transducer can measure 75mV or 0-300V dc voltage and output 4-20mA/0-5V.

  • Input:DC 4~20mA,0~20mA

  • Output:DC 0-20mA/4-20mA/0-5V/0-10V

  • Power supply:AC 85~265V,DC 100V~350V,DC 24V

  • Overload:1.2 times of rated value

Parameters of BD-DI Single Phase DC Current Transducer


Type

BD-Dl,BD-DV

Accuracy

0.5 Class,0.2 Class

Input

Signal

DC 4~20mA,0~20 mA
  DC 0~10V,0~75mV
  DC 0~300V

Overload

Current:continuous   1.2 times, instant current 10 times per second
  Voltage:continuous 1.2 imes, instant Voltage 10 times per second

Frequency

45Hz~65Hz

Output

Signal

DC   4~20mA,0~20mA,0~5V,0~10V

Load

Current   output<600Ω,Voltage output1000Ω

Optional function

/

Power Supply

AC 85~265V,DC   100V~350V,DC 24V

Temperature drift   coefficient

0.2class≤100ppm℃,0.5class≤200ppm℃

Response time

<400ms

Insulation resistance

≥100MΩ

Power   frequency  withstand voltage

Auxiliary power   supply/Input / Output 2kV/1min,50Hz

Environment

Temperature

Work;-10℃~55℃ Store:-25℃~70℃

Humidity

≤93%RH,places   without condensation and corrosive gas

Altitude

≤2500m

Installation mode

TS35mm din rail or   screw fixing


Video of DC Current Transducer


Wiring of BD-DI Single Phase DC Current Transducer

BD-DI Single Phase DC Current Transducer interface 1/2 is power supply L/N(AC 85~265V,DC 100V~350V,DC 24V),interface 3/4 is the current input DC 4~20mA,0~20mA,interface 5/6 is the first channel analog output DC 4~20mA,0~20mA,0~5V,0~10V.


Wiring of BD-DI Single Phase DC Current Transducer


Application of BD-DI Single Phase DC Current Transducer


  • The field of industrial automation

  • Photovoltaic and wind power industry

  • Metallurgy, electric power, oil field

  • Railway locomotives, shipping industry

Package of BD-DI Single Phase DC Current Transducer


MINIMUM PACKAGEDc Ct SensorDc Current Measurement Sensor100a Dc Current SensorDc Current Sensor Circuit
MINIMUM PACKAGEPackage dimensions(1 PC)
17*15.5*12.5cm
Package Weight(1 PC)
0.25Kg
WHOLE BOX PACKAGEPackage dimensions(10 PCS)
45.5*26*19.5cm