As one of the established hall sensor manufacturers, Acrel offers AHKC Series Hall sensor, which is mainly suitable for the isolation conversion of complex signals such as AC, DC, and pulse. Through the Hall effect principle, the converted signal can be directly collected and accepted by various acquisition devices such as AD, DSP, PLC, and secondary instruments.
Specification/Size | Outline size | Through size | Mounting size | |||||
W | H | D | a | e | φ | M | N | |
AHKC-EKA | 60 | 64 | 16 | / | / | 20 | 47 | / |
AHKC-EKAA | 60 | 64 | 16 | / | / | 20 | 47 | / |
AHKC-EKDA | 60 | 64 | 16 | 20 | 47 | |||
AHKC-EKB | 100 | 102 | 24 | / | / | 40 | 80 | / |
AHKC-EKBA | 100 | 102 | 24 | / | / | 40 | 80 | / |
AHKC-EKBDA | 100 | 102 | 24 | 40 | 80 | |||
AHKC-EKC | 115 | 110 | 27 | 55 | 95.5 | |||
AHKC-EKCA | 115 | 1i0 | 27 | 55 | 95.5 | |||
AHKC-EKCDA | 115 | 110 | 27 | 55 | 95.5 | 30 | ||
AHKC-K | 127 | 63 | 25 | 64 | 16 | / | / | 30 |
AHKC-KAA | 127 | 63 | 25 | 64 | 16 | / | / | 30 |
AHKC-KDA | 127 | 63 | 25 | 64 | 16 | 46 | ||
AHKC-H | 149 | 79 | 25 | 82 | 32 | / | / | 46 |
AHKC-KA | 176 | 95.5 | 29 | 104 | 36 | / | / | 60 |
AHKC-HB | 204 | 111.5 | 29 | 132 | 52 | / | / | 48*2 |
AHKC-HBAA | 204 | 111.5 | 29 | 132 | 52 | 48x2 | ||
AHKC-HBDA | 204 | 111.5 | 29 | 132 | 52 | 48x2 | ||
AHKC-E | 53 | 72 | 16 | / | / | 21 | 47 | / |
AHKC-LT | 90 | 73.5 | 25 | / | / | 32.5 | 74.5 | 71 |
AHKC-BS | 43 | 32.5 | 19 | 20.5 | 10.5 | / | / | / |
AHKC-BSA | 43 | 32.5 | 19 | 20.5 | 10.5 | / | / | / |
AHKC-F | 74 | 57 | 22 | 43 | 13 | / | / | 22 |
AHKC-FA | 94 | 60.5 | 26.5 | 52 | 15 | / | 83 | 28 |
AHKC-HAT | 94 | 76.5 | 24 | 52.5 | 32 | / | 83 | 28 |
Hall current sensor is a magnetic field sensor made according to the Hall effect. It has two working modes, open loop (straight) and closed loop (magnetically balanced). The advantages of the direct-release Hall sensor are that the circuit form is simple and the cost is relatively low; its disadvantages are poor accuracy and linearity, slow response time and large temperature drift. In order to overcome its shortcomings, closed-loop (magnetically balanced) Hall current sensors have appeared.
It depends your input signal and output signal you need.
Split type open loop,Close type open loop,Close type close loop.
DC ±12V, ±15V, ±24V power supply
Industrial control,process control,battary monitor,locomotive application,converter,wayside application.
Any IoT energy management system problem pls contact us, our experts will reply you within 24 hours.
Tel:
+86-18761599716
E-mail:
Address:
No.5 Dongmeng Road, Nanzha Street, Jiangyin City, Jiangsu Province, China.