Acrel AMB Series Data Center Busway Monitoring Module is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time.


AMB Series Data Center Busway Monitoring Module For Sale

Simple, multi-functional, fast, economical, parameter monitoring, fault alarm.

AMB Series Data Center Busway Monitoring Module Data Sheet

Technical parametersAMB100-D-□/AMB110-D-
Measured parametersVoltage,current, power,electric energy,on/off status
VoltageRated value48VDC,240VDC,336VDC
Range±20%
Overloading1.2 times than the rated voltage value continuously or 2times than the rated voltage value instantaneously persecond
CurrentCT5V(Hall transducer)
Range
Overloading1.2 times than the rated current value continuously or 10times than the rated current value instantaneously persecond
Measurement accuracyVoltage/current: grade 0.5;power/energy: grade 1.0
Auxiliary power supplyAMB100/110-D(/W): trigered upon receipt of requestsignal
AMB100/110-D(/W)-P1:follow the bus bar voltage
FunctionsTemperaturedetection-20-150℃
Leakage5VDC,3 leakage inputs
Digital input4 dry-contact inputs
Digital output2relayoutputs;contactcapacity:3A/30VDC,3A/250VDC
CommunicationVia RS485/Modbus-RTU or LORA antenna
InstallationUse DIN35mm rail
ProtectionIP20
Pollution level2
EnvironmentTemperature/humidity/altitudeWorking temperature:-20-+60℃Storage temperature:-25-+70℃Relative humidity:<93%Altitude:≤2500m
SafetyInsulationThe minimum insulation resistance between all terminalsand conductive components of the shell is 100MO.
Withstanding voltageWhen a voltage of 2kV AC is applied between thevoltage/ current input, relay output,RS485 port,auxiliarypower supply and digital inputs,the leakage shall be lessthan 2mA and no breakdown or flashover shall occur in1min.
ElectromagneticimmunityElectrostatic discharge immunityClass 4
Radio frequency electromagnetic immunityClass 3
Transient burst immunityClass 4
Surge immunityClass 4


Benefits of Data Center Busways

Benefits of Data Center Busways

Acrel Data Center Busway Monitoring system is a common name for the power supply and distribution system at the end of the data center. This system is mainly used for power distribution at the end of the cabinet in the data center room. It has the characteristics of simplicity, multi-function, speed and economy. There are many advantages. AMB intelligent small busbar management system is a solution for the monitoring requirements of data center intelligent small busbars. It can monitor various parameters during the operation of the busbar, and give an alarm when a fault occurs, so as to ensure the stable operation of the system.


AMB Series Data Center Busway Monitoring Module FAQs

  • What standard is the main reference for the design of the AMB intelligent small bus monitoring solution?

    China Mobile Communication Enterprise Standard QB-H-008-2018 Rack Distrubution Bus System.


  • What are the functional requirements for intelligent monitoring of the plug-in box?

    Remote measurement: output branch single-phase voltage,current, active power, real-time operating temperature at the pins of the plug-in box


  • What are the functional requirements for intelligent monitoring of the start-end box

    Remote measurement: intput the three-phase voltage, current, active power, active energy, power factor, temperature etc.


  • What does a data center monitor module do?

    By virtue of 2 RJ45 communication ports (1 in and 1 out) and MODBUS-RTU protocol, it is easy and reliable to upload the monitoring data to the touch screen of the main controller for centralized monitoring.