Acrel BA series AC Current Transducer apply the principle of electromagnetic induction to measure the AC current in the power grid in real time, and use constant current and linear compensation technology to isolate and convert it into a standard DC signal output. 24V or 12V safe voltage power supply, can be widely used in industrial automation field.
Tpye | BA05-Al/(V) | BA10-Al/I(V) | BA20-Al/(V) | BA50-Al/I(V) | BA50L-A/I(V) | |
AuxiliaryPower | DC 12V/24V | DC 12V/24V | DC 12V/24V | DC 12V/24V | DC 12V/24V | |
Consumption | ≤1W | ≤1W | ≤1W | ≤1W | ≤1W | |
Through-hole size | Φ5mm | Φ10mm | Φ20mm | Φ50mm | Φ50mm | |
Input | Current | AC0~(0.5-10)A | AC 0~(8-50)A | AC0~(40-200)A | AC 0~(60-600)A | AC0~(0.1~1)A(imitation of leakage cuments) |
Output | Nominal value | DC4-20mA, or 0-20mA, 0-5V, 0-10V etc | ||||
Load resistance | Current output≤500Ω, Voltage output≥1kΩ | |||||
Accuracy Class | 0.50% | |||||
Response time | ≤350ms | |||||
Temperature | Operation: -10 to +55℃ Storage:-25 to+70℃ | |||||
Temperature coefficient | ≤200ppm/℃ | |||||
Installation | (Rail)DIN35, fix on cubicle with screws | |||||
Standards | GB/T13850 CE |
BA series current sensor uses the principle of electromagnetic induction to measure the AC current in the power grid in real time and uses constant current and linear compensation technology to isolate andtransformitinto a standard DC signal output, or through the RS485 interface (Modbus-RTU protocol) to transmit the measurement data. DC24V or 12V safety voltage power supply, can be widely used in the field of industrial automation. BA50L is an AC residual current transformer, which mainly detects the leakage current of the electrical system, cangraspthestatus of electrical circuits and equipment at any time, and prevent fires and other accidents caused by leakage.
The transformer is a large current and a small current (1A or 5A) for measurement and protection circuits. The transducer converts the input current into a weak current communication signal (0-20mA or 0-5V) and transmits it to the subsequent circuit for processing.
Apply the principle of electromagnetic induction to measure the AC current in the power grid in real time, and convert it into a standard DC signal output.
Convert industrial high current and high voltage into analog signals that can be measured, which is safer and more accurate
It depends your input current and output signal you need, including power supply and cable size.
Any IoT energy management system problem pls contact us, our experts will reply you within 24 hours.
Tel:
+86-18761599716
E-mail:
Address:
No.5 Dongmeng Road, Nanzha Street, Jiangyin City, Jiangsu Province, China.